Preview

Endodontics Today

Advanced search

Design features of the rotary endodontic instruments system ProFile

Abstract

Design features of the endodontic instrument determine its essential properties. Information about these design features carries inference about instrument properties and makes possible a comparative analysis of instruments with different design. The aim of the present work is a quantitative study and analysis of the Pro-File instruments design features. Thirty instruments of different size and taper have been included in this study. SEM examination of all instruments and their cross-sections was made to determine the following design parameters: tip angle, fluting angle, pitch length, fluting depth, internal and external diameters and the angles of cutting blade. Design features analysis of the ProFile instruments allows pointing out its outstanding characteristics: 1) high flexibility; 2) high cyclic fatigue resistance; 3) the ability to preserve the original root canal anatomy; 4) low cutting ability; 5) substantial screwing-in effect of the instruments of greater sizes.

About the Authors

Т. Беляева
ФПДО ГБОУ ВПО МГМСУ им. А.И. Евдокимова
Russian Federation


Е. Ржанов
ФПДО ГБОУ ВПО МГМСУ им. А.И. Евдокимова
Russian Federation


References

1. Wan J., Rasimick B. J., Musikant B. L., Deutsch A. S. A comparison of cyclic fatigue resistance in reciprocating and rotary nickel-titanium instruments // Aust Endod J. 2011. №37 (3). Р. 122-127.

2. Lee M. H., Versluis A., Kim B. M., Lee C. J., Hur B., Kim H. C. Correlation between experimental cyclic fatigue resistance and numerical stress analysis for nickel-titanium rotary files // J Endod. 2011. №37 (8). Р. 1152-1157.

3. Shen Y., Qian W., Abtin H., Gao Y., Haapasalo M. J. Fatigue testing of controlled memory wire nickel-titanium rotary instruments // J Endod. 2011. №37 (7). Р. 997-1001.

4. Huang H. M., Chang W. J., Teng N. C., Lin H. L., Hsieh S. C. Structural analysis of cyclicloaded nickel-titanium rotary instruments by using resonance frequency as a parameter // J Endod. 2011. №37 (7). Р. 993-996.

5. Adorno C. G., Yoshioka T., Suda H. Crack initiation on the apical root surface caused by three different nickel-titanium rotary files at different working lengths // J Endod. 2011. №37 (4). Р. 522-525.

6. Yum J., Cheung G. S., Park J. K., Hur B., Kim H. C. Torsional strength and toughness of nickel-titanium rotary files // J Endod. 2011. №37 (3). Р. 382-386.

7. Setzer F. C., Kwon T. K., Karabucak B. Comparison of apical transportation between two rotary file systems and two hybrid rotary instrumentation sequences // J Endod. 2010. №36 (7). Р. 1226-1229.

8. Al-Omari M. A., Aurich T., Wirtti S. Shaping canals with ProFiles and K3 instruments: does operator experience matter? // Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010. №110 (3). Р. 50-55.

9. Ersev H., Yilmaz B., Ciftçioğlu E., Ozkarsli S. F. A comparison of the shaping effects of 5 nickel-titanium rotary instruments in simulated S-shaped canals // Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010. №109 (5). Р. 86-93.

10. Stewart J. T., Lafkowitz S., Appelbaum K., Hartwell G. Distortion and breakage of Liberator, EndoSequence, and ProFile systems in severely curved roots of molars // J Endod. 2010. №36 (4). Р. 729-731.

11. Oh S. R., Chang S. W., Lee Y., Gu Y., Son W. J., Lee W., Baek S. H., Bae K. S., Choi G. W., Lim S. M., Kum K. Y. A comparison of nickel-titanium rotary instruments manufactured using different methods and cross-sectional areas: ability to resist cyclic fatigue // Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010. №109 (4). Р. 622-628.

12. Plotino G., Grande N. M., Melo M. C., Bahia M. G., Testarelli L., Gambarini G. Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature // Int Endod J. 2010. №43 (3). Р. 226-230.

13. Vahid A., Roohi N., Zayeri F. A comparative study of four rotary NiTi instruments in preserving canal curvature, preparation time and change of working length // Aust Endod J. 2009. №35 (2). Р. 93-97.

14. Chow D. Y., Stover S. E., Bahcall J. K., Jaunberzins A., Toth J. M. In vitro comparison of the rake angles between K3 and ProFile endodontic file systems // J Endod. 2005. №31 (3). Р. 180-182.

15. Sonntag D. Schneidengeometrie und Effizienz voll-rotierender Nickel-Titan-Feilen // Endodontie. 2003. №12. Р. 229-241.

16. Беляева Т. С., Ржанов Е. А. Конструктивные особенности вращаемых (ротационных) эндодонтических инструментов // Эндодонтия. 2010. №4. С. 3-12.

17. Beljaeva T. S., Rzhanov E. A. Konstruktivnye osobennosti vrashchaemyh (rotacionnyh) endodonticheskih instrumentov // Endodontija. 2010. №4. S. 3-12.


Review

For citations:


 ,   Design features of the rotary endodontic instruments system ProFile. Endodontics Today. 2012;10(4):9-17. (In Russ.)



Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1683-2981 (Print)
ISSN 1726-7242 (Online)