Histological and histomorphometric investigation of SiO2 nanoparticle-coated PEEK implants on the osseointegration in rabbit
https://doi.org/10.36377/ET-0169
Abstract
INTRODUCTION. Metal, polymer, and ceramic implants are examples of biocompatible implants that are frequently suggested to enhance osseointegration and promote bone formation. The goal of this study was to improve osseointegration by developing a new interface. This contact exists between bone tissue and the polymeric component. Silicon dioxide material is applied to PEEK (polyether ether ketone) plastic in this work coat.
MATERIALS AND METHODS. Thirty New Zealand rabbits received sixty implants. Each rabbit has two implants in its tibia. Ten rabbits were scarified at two, four and six, weeks following implantation. The left tibia implant was experimental (coated with silicon dioxide), while the right tibia implant was control (uncoated) for every animal. Following hematoxylin and eosin staining, each section was histologically inspected and evaluated for histomorphometric analysis to count bone cells (osteoblast, osteocyte, and osteoclast) and the area of new bone is formed.
RESULTS. In comparison to control groups, histological results for silicon dioxide-coated PEEK implants showed a more rapid of bone growth, mineralization, and maturation. Significant difference of histomorphometric examination of every bone parameter was very high between the control and experimental groups during the course of all healing intervals.
CONCLUSIONS. According to the current study, the nano-silicon dioxide coating promotes faster osseointegration than an uncoated implant, improving bone formation and increasing the healing rates.
About the Authors
Y. M. HaiderIraq
Yagthan Mohammed Haider – Lecturer, Department of Prosthodontic, College of Dentistry
Baghdad, Iraq
Competing Interests:
The authors report no conflict of interest.
G. H. Jani
Iraq
Ghasak H. Jani – Assistant Professor, Department of Prosthodontic, College of Dentistry
Baghdad, Iraq
Competing Interests:
The authors report no conflict of interest.
A. A. Fatalla
Iraq
Abdalbseet A. Fatalla – Professor, Department of Prosthodontic, College of Dentistry
Baghdad, Iraq
Competing Interests:
The authors report no conflict of interest.
R. A. Mohammed
Iraq
Raghad Abdullrazzaq Mohammed – Professor, Department of Conservative, College of Dentistry
Baghdad, Iraq
Competing Interests:
The authors report no conflict of interest.
References
1. Liu Y., Rath B., Tingart M., Eschweiler J. Role of implants surface modification in osseointegration: A systematic review. J Biomed Mater Res A. 2020;108(3):470–484. https://doi.org/10.1002/jbm.a.36829
2. Jani G.H., Fatalla A.A. Surface Characterization of PEKK Modified by stron-tium – hydroxyapatite coating as implant material Via the magnetron sputtering Deposition technique. Journal of Baghdad College of Dentistry. 2022;34(2):25–36. https://doi.org/10.26477/jbcd.v34i2.3143
3. Oshida Y, Tuna EB, Aktören O, Gençay K. Dental implant systems. Int J Mol Sci. 2010;11(4):1580–678. https://doi.org/10.3390/ijms11041580
4. Alheeti O.A.R., Jani G.H., Qustanteen F.R. The effects of selenium nanoparticles on the osseointegration of a titanium implant in rabbits: A histomorphometric investigation. Dentistry 3000. 2024;12(2):730. https://doi.org/10.5195/d3000.2024.730
5. Papaspyridakos P., Mokti M., Chen C.J., Benic G.I., Gallucci G.O., Chronopoulos V. Implant and prosthodontic survival rates with implant fixed complete dental prostheses in the edentulous mandible after at least 5 years: a systematic review. Clin Implant Dent Relat Res. 2014;16(5):705–717. https://doi.org/10.1111/cid.12036
6. Frisardi G., Barone S., Razionale A.V., Paoli A., Frisardi F., Tullio A. et al. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis. Head Face Med. 2012;8(1):18. https://doi.org/10.1186/1746-160X-8-18
7. Kamil N.B., AL-Ghaban N.M., Aamery A. Osseointegration effects of whey protein (histological and histomorphological observations): An experimental study on rabbits. Journal of Baghdad College of Dentistry. 2023;35(3):28–36. https://doi.org/10.26477/jbcd.v35i3.3449
8. Kamil N.B., AL-Ghaban N.M. Evaluation of the effects of whey protein and moringa oleifera leaves extract mixture on osseointegration in rabbits. Iran Biomed J. 2023;28(2-3):82–89. https://doi.org/0.61186/ibj.4025
9. Jemat A., Ghazali M.J., Razali M., Otsuka Y. Surface modifications and their effects on titanium dental implants. Biomed Res Int. 2015;2015:791725. https://doi.org/10.1155/2015/791725
10. Goyal N., Kaur R. Effect of various implant surface treatments on osseointegration – A literature review. Indian J Dental Sci. 2012;4(1):154–157.
11. Rupp F., Liang L., Geis-Gerstorfer J., Scheideler L., Hüttig F. Surface characteristics of dental implants: A review. Dent Mater. 2018;34(1):40–57. https://doi.org/10.1016/j.dental.2017.09.007
12. Bosco R., Van Den Beucken J., Leeuwenburgh S., Jansen J. Surface engineering for bone implants: A trend from passive to active surfaces. Coatings. 2012;2(3):95–119. https://doi.org/10.3390/coatings2030095
13. Schupbach P., Glauser R., Bauer S. Al2O3 particles on titanium dental implant systems following sandblasting and acid-etching process. Int J Biomater. 2019;2019:6318429. https://doi.org/10.1155/2019/6318429
14. Owonubi S.J., Agwuncha S.C., Fasiku V.O., Mukwevho E., Aderibigbe B.A., Sadiku E.R., Bezuidenhout D. Biomedical applications of polyolefins. In: Ugbolue S.C.O. (ed.) Polyolefin Fibres. 2 nd ed. Elsevier Ltd.; 2017, pp. 517–538. https://doi.org/10.1016/B978-0-08-101132-4.00017-5
15. Durham J.W. 3 rd , Montelongo S.A., Ong J.L., Guda T., Allen M.J., Rabiei A. Hydroxyapatite coating on PEEK implants: Biomechanical and histological study in a rabbit model. Mater Sci Eng C Mater Biol Appl. 2016;68:723–731. https://doi.org/10.1016/j.msec.2016.06.049
16. Torres J.L., Gehrke S., Guirado J.L.C., Aristazábal L.F.R. Evaluation of four designs of short implants placed in atrophic areas with reduced bone height: A three-year, retrospective, clinical and radiographic study. Br J Oral Maxillofac Surg. 2017;55(7):703–708. https://doi.org/10.1016/j.bjoms.2017.05.012
17. Tomaszewski P.K., Lasnier B., Hannink G., Verkerke G.J., Verdonschot N. Experimental assessment of a new direct fixation implant for artificial limbs. J Mech Behav Biomed Mater. 2013;21:77–85. https://doi.org/10.1016/j.jmbbm.2013.02.012
18. Jeong S.-M., Choi B.-H., Li J., Kim H.-S., Ko C.-Y., Jung J.-H. et al. Flapless implant surgery: an experimental study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;104(1):24–28. https://doi.org/10.1016/j.tripleo.2006.11.034
19. Jawad S.N., Abdullah B.H. Computer assisted immunohistochemical score prediction via simplified image acquisition technique. J Bagh Coll Dent. 2017;29(1):83–88. https://doi.org/10.12816/0038631
20. Atsumi M., Park S.H., Wang H.L. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants. 2007;22(5):743–754.
21. Jassim M.M., Hamad T.I. In vitro assessment of some properties of biocompatable polymer dental implant consisting from poly ether ketone (Peek) and silicon carbide nanofiller. Indian J Public Health Res Dev. 2019;10(10):2772–2777. https://doi.org/10.5958/0976-5506.2019.03289.3
22. Ghiban B., Jicmon G., Coşmeleaţa G. Structural investigation of electrodeposited hydroxyapatite on titanium supports. Rom J Physiol. 2006;51;(1-2):187–196. Available at: https://rjp.nipne.ro/2006_51_1-2/0187_0196.pdf (accessed: 15.12.2025).
23. Ibrahim S.W., Al-Nakkash W.A., Al Ghaban N.M. Histological assessment of nano hydroxyapatite, chitosan and collagen composite coating on commercially pure dental implants in comparison with nanohyroxyapatite coating. Int J Sci Res. 2017;6(7):ART20175552. https://doi.org/10.21275/art20175552
24. Inzunza D., Covarrubias C., Von Marttens A., Leighton Y., Carvajal J.C., Valenzuela F. et al. Synthesis of nanostructured porous silica coatings on titanium and their cell adhesive and osteogenic differentiation properties. J Biomed Mater Res A. 2014;102(1):37–48. https://doi.org/10.1002/jbm.a.34673
25. Jani G.H., Al-Ameer S.S., Jawad S.N. Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating. Journal of Baghdad College of Dentistry. 2015;27(1):26–31. Available at: https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/631 (accessed: 15.12.2025).
Review
For citations:
Haider Y.M., Jani G.H., Fatalla A.A., Mohammed R.A. Histological and histomorphometric investigation of SiO2 nanoparticle-coated PEEK implants on the osseointegration in rabbit. Endodontics Today. 2026;24(1):136-142. https://doi.org/10.36377/ET-0169

























