INTRODUCTION. One of the main stages of successful endodontic treatment is high-quality mechanical treatment of root canals. А large number of various rotary Ni-Ti files in the dental market poses a difficult choice for the doctor, especially in the context of import substitution. It is necessary to have knowledge about the effectiveness of different system of instruments in a particular clinical case. AIM. With the help of scanning electronic mycoroscopy and computer microtomography, to analyze the quality of mechanical treatment of the root canal with files of domestic and foreign production.
MATERIALS AND METHODS. During the study, single-root and multi-root teeth with different root canal curvature were selected, which were distributed according to the Ni-Ti file system used: group 1 – RM files (RusMed), group 2 – ProTaper Universal (Dentsply Mallifier), group 3 – M-two (VDW).
RESULTS. The analysis of scanning electron microscopy of tooth showed that the largest number of open dentine tubules is determined when treating the root canal with instruments of the group 1 (55.4±1.37) and group 3 (60.25±1.59). The centering ability with a curvature of the root canal of 20–25° had no significant differences between the tools used. With a curvature of the root canal of 40–45°, the value of this parameter decreased significantly in all groups of instruments, it was greatest in the groups 1 and 3.
CONCLUSION. It was revealed that the best quality of mechanical treatment of the root canal was obtained using RM-files and Mtwo in samples with a channel curvature of up to 25°.

About the Authors

O. A. Antonova
Russian University of Medicine
Russian Federation

Olesya A. Antonova – Assistant of the Department of Therapeutic Dentistry and Endodontics

4, Dolgorukovskaya St., Moscow 127006



V. A. Voinova
Russian University of Medicine
Russian Federation

Viktoriia A. Voinova – Student of the Department of the Faculty of Dentistry

4, Dolgorukovskaya St., Moscow 127006



Yu. A. Mitronin
Russian University of Medicine
Russian Federation

Yuriy A. Mitronin – Postgraduate Student of the Department of Therapeutic Dentistry and Endodontics; assistant of the Department of Propaedeutics of Therapeutic Dentistry

4, Dolgorukovskaya St., Moscow 127006



References

1. Orekhova L.Yu., Vashneva V.Yu., Porkhun T.V., Zaitseva Yu.A. Comparative effectiveness of root canal machining with modern ni-ti tools. Endodontics Today. 2020;18(2):10–15. (In Russ.) https://doi.org/10.36377/1683-2981-2020-18-2-10-15

2. Belyaeva T.S., Zablotskaya N.V., Mitronina N.V., Baitokova A.A., Alimukhamedova S.Sh. Cycling fatigue resistance of various reciprocating endodontic instrument systems (laboratory study). Cathedra. Dental Education. 2023;(85):44–49. (In Russ.)

3. Redinova T.L., Pudova E.I., Sharifullina I.С., Yesyunina A.A., Zagrebin I.V. The frequency of occurrence of various variants of the structure of root canals and methods of their mechanical treatment in the practice of a dentist-therapist. Endodontics Today. 2022;20(3):215–221. (In Russ.) https://doi.org/10.36377/1726-7242-2022-20-3-215-221

4. Pyatkova I.V., Orekhova L.Yu., Porkhun T.V., Silin A.V. Determination of indications for the choice of the preparation method of the root canal system with rotation and reciprocation instruments. Endodontics Today. 2020;18(1):21–26. (In Russ.) https://doi.org/10.36377/1683-2981-2020-18-1-21-26

5. Mitronin A.V., Vedmitskaya V.V., Khromova L.A. Assessment of the apical part of the roots after their instrumentation by different endodontic systems. Endodontics Today. 2019;17(3):3–7. (In Russ.) https://doi.org/10.36377/1683–2981-2019-17-3-3-7

6. Mitronin A.V., Sobkina N.A., Pomeshchikova N.I., Dmitrieva L.A. Use of computer microtomography to assess the quality of endodontic tooth treatment using modern instruments. Endodontics Today. 2018;16(1):22–26. (In Russ.) Available at: https://www.endodont.ru/jour/article/view/173 (accessed: 23.06.2024).

7. Devyatnikova V.G. An experimental study of the quality of machining of root canals with reciprocal and cyclic endodontic systems. Sovremennaya Stomatologiya. 2020;(2):68–72. (In Russ.)

8. Giuliangeli D.F., Romagnoli K., Cortes D.G.N., Interliche R. Root perforation sealing using MTA Repair (case report). Cathedra. Dental Education. 2022;(82):6–8. (In Russ.)

9. Ostanina D.A., Mitronin Yu.A., Anisimova D.V., Mitronin A.V. Optimization of difficult endodontic treatment with nickel-titanium files in martensitic and austenitic phase. Endodontics Today. 2024;22(1):4–10. (In Russ.) https://doi.org/10.36377/ET-0004

10. Dombrovskaya Yu.A., Paderina T.O., Benken K.A., Lubskaya E.Yu., Silin A.V. Comparative morphometric characteristics of the working surface of endodontic rotary nickel-titanium instruments after maximum cyclic loading. Endodontics Today. 2022;20(1):12–19. (In Russ.) https://doi.org/10.36377/1683-2981-2022-20-1-12-19


Review

For citations:


Antonova O.A., Voinova V.A., Mitronin Yu.A. Comparative analysis of the effectiveness of mechanical treatment of root canals by various Ni-Ti file systems. Endodontics Today. 2024;22(3):206-211. (In Russ.) https://doi.org/10.36377/ET-0032



Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1683-2981 (Print)
ISSN 1726-7242 (Online)